  • BS ISO 7409:2018 pdf free.Fertilizers一Marking 一Presentation and declarations. Marking can take the form of package markings, quality assurance documents, labels, electronic labels, etc. The information can be added to bags by printing, labels, stickers, etc. The use of electronic labels, such as two-dimensional (2D) codes, is encouraged. Electronic labels should be legible and conspicuous on a discrete area of the principal display panel and shall include, at a minimum, the information related to package markings. 7 Pre-marked containers 7.1 Containers holding more than 25 kg (or 25 I) of fertilizer 7.1.1 Marking technical details Position: A rectangular space for marking shall be located in the centre of one of the main faces of the container/label. The edges of the space shall be parallel to the edges of the container. Measurement: Its edges shall be at least 65 % of the length of the container. The total area for marking shall be at least 10 % of the face selected. Label information: The technical information of the label on the container should be easy to read. Any picture, brand or logo used in the marking should not obstruct the quick identification of text messages. Declarations shall be marked within the above-mentioned…

  • BS ISO 6280:2018 pdf free.Plain bearings  – Requirements and guidance on backings for thick-walled multilayer bearings. There are no normative references in this document. 3 Terms and definitions No terms and definitions are listed in this document. ISO and IEC maintain terminological databases for use in standardization at the following addresses: — ISO Online browsing platform: available at https://www.iso.org/obp — IEC Elect ropedia: available at http:J/www.electropedia.org/ 4 Backing materials 4.1 General Steel and cast steel, cast iron with lamellar and spheroidal graphite as well as cast copper alloys are used as backing materials. For cast iron backing, additional dovetailed grooves may be used on bond surface for mechanical anchoring. 4.2 Steel and cast steel Before lining, the backing is heat-treated for normalizing and Stresses relieving. Typical contents of elements for bonding: — C < 0.25 % (mass fraction); — Cr 1,1 % (mass fraction); — Ni < 0,5 % (mass fraction). The hydrogen contents of a backing having a thickness of 40 mm or more shall be not more than 1,7 ppm. A properly-controlled process shall be used to reduce the hydrogen content to a level that ensures trouble-free running of the bearing during its initial period operation. The bond…

  • BS ISO 1835:2018 pdf free.Round steel short link chains for lifting purposes一Medium tolerance sling chains – Grade 4, stainless steel. The bases for calculation of the values for the dimensions listed in Table 1 are given in Annex A. The bases for calculation of the values for the mass per metre listed in Table B.1 are given in Annex B. The nominal diameter, dn, of the sling chain corresponds to the nominal diameter of the steel wire as presented in ISO 16124, or bar as presented in ISO 1035-1, from which the sling chain is made.Preferred nominal diameters are given in Table 1 column 1. Other nominal diameters may be used, provided the corresponding dimensions and tolerances are calculated in accordance with Annex A. The sling chain shall comply with the requirements of ISO 1834 as well as those of this document. 5.2 Material The steel used shall be austenitic stainless steels with molybdenum and shall be resistant against intergranular corrosion, for example the steel with the ISO name X6CrNiMoTi17-12-2 and the ISO number 4571-316-35-I according to ISO 15510. After solution annealing intergranular corrosion is unlikely at a service temperature of +400 °C and with an extra low carbon content…

  • BS EN ISO 6892-2:2018 pdf free.Metallic materials – Tensile testing Part 2: Method of test at elevated temperature. The force-measuring system shall be set to zero after the testing equipment has been assembled but before the test piece is actually placed in the gripping jaws. Once the force zero point has been set, the force-measuring system may not be changed in any way during the test. NOTE The use of this method ensures that the weight of the gripping system is compensated in the force measurement and that any force resulting from the clamping operation does not affect the force zero point. 10.2 Gripping of the test piece, fixing of the extensometer and heating of the test piece, not necessarily in the following sequence 10.2.1 Method of gripping For requirements concerning the method of gripping, see ISO 6892-i. NOTE Maintaining a very small tensile load (e.g. test machine in load control) during heating period and soaking time can prevent possible compressive stresses due to thermal expansion. 10.2.2 Fixing of the extensometer and establishing the gauge length 10.2.2.1 General Different methods of establishing the extensometer gauge length are used in practice. This can lead to minor differences in the test results….

  • BS EN ISO 8654:2018 pdf free.Jewellery – Colours of gold alloys – Definition, range of colours and designation [ISO 8654:2018). The samples to be measured shall have a flat and polished surface to be used as a measurement area. The measurement area shall be exempt of defect. The finishing (polishing and washing) shall be (re)done until a mirror surface is achieved (Y reaches a constant value). After polishing, the sample colour measurement shall be made within 120 mm maximum. NOTE Polishing, washing and environment conditions can greatly affect the colour. 5.2.1.2 Metallographic preparation Metallographic preparation is made with a final polishing with broadcloth charged with an abrasive solution. The solution contains 1 I.Im sized abrasive particles. 5.2.1.3 Sample cleaning The recommended sample cleaning is done by gently wiping the surface with a clean soft cloth (microflbre) and some isopropylalcohol (IPA). 5.2.2 Measurement apparatus 5.2.2.1 General The measurement apparatus for the colour measurement of a gold alloy shall be in accordance to CIE Publication No. 15. 5.2.2.2 Reference apparatus The reference apparatus for the colour measurement of a gold alloy is an integrating sphere spectrophotometer able to measure spectral reflectance, with a measurement geometry compatible with designation di:8° or 8°:di (specular…

  • BS ISO 15461:2018 pdf free.Steel forgings一Testing frequency, sampling conditions and test methods for mechanical tests. 5.1 For the testing frequency of room temperature tensile tests and of impact tests, the requirements given in JJ1 to apply. 5.1.1 The product standard or order shall specify, by reference to the appropriate symbol(s) in Table 1. column 1, the following: a) the composition of the test unit as defined in Table 1. columns 2 to 8; b) whether uniformity checks by hardness tests in accordance with Table 1. column 9 are required and, if so, the percentage of products to be subjected to the hardness tests; c) the number of sample products to be taken from the test unit. (See the explanations in Table 1. footnote a, for replacing the letter “n of the symbol by the mass of the test unit up to which the taking of one sample product is sufficient.) NOTE Less stringent requirements for the composition of the test unit can be compensated by more stringent requirements for the number of sample products to be tested. Therefore, for example, a test unit characterized by the symbol CH5 can be regarded as equivalent to a test unit characterized by the…

  • BS ISO 13605:2018 pdf free.Solid mineral fuels – Major and minor elements in coal ash and coke ash – Wavelength dispersive x-ray fluorescence spectrometric method. Discs may be prepared by the casting or press-quenching technique. Both methods will produce glass discs of adequate quality. If the casting technique is used, the sample may be fused with the flux in a crucible and then poured into a separate mould; if an appropriately shaped crucible is used, the fusion may be carried out and the glass allowed to cool in the same crucible. A conventional electric furnace, high-frequency furnace, or gas burner may be used for heating. Disc-making machines are available commercially, and these may be used to fuse and cast the discs. Prior to measurement, discs shall be inspected visually, paying particular attention to the analytical surface. The discs shall not contain undissolved material, and shall be whole and free from crystallization and bubbles. Defective discs shall be re-fused or discarded and substitute discs prepared. Laboratory-prepared ashes for XRF analysis should be freshly prepared; if not, It will be necessary to reheat these to the ashing temperature and hold for 15 mm at this temperature prior to preparation of the XRF…

  • BS ISO 10804:2018 pdf free.Restrained joint systems for ductile iron pipelines – Design rules and type testing. 4.1 All restrained joints for ductile iron pipes, fittings and other components shall be designed in accordance with this clause. If the design of a restrained joint has been tested and successfully used for a minimum of 10 years, a type test as described in Clause 5 is only required for a significant change in the design which could adversely affect the performance of the restrained joint. 4.2 The minimum thickness of the spigot for restrained joints shall allow any necessary welding or loading from attachments (e.g. gasket teeth). This may result in a pipe thicker than the corresponding pressure class thickness of the pipe. The manufacturer shall declare the pipe thickness for their restrained joints. 4.3 The design safety factors with respect to failure against axial forces due to internal pressure shall be such that the joints shall withstand a type test of 1,5 times the allowable operating pressure (PFA) pIus 5 bar (5 x 105 Pa).1) 4.4 The joints shall be type tested to a negative pressure of 0,9 bar (9 x 104 Pa) below atmospheric pressure [approximately 0,1 bar (104…

  • BS ISO 8637-3:2018 pdf free.Extracorporeal systems for blood purification Part 3: Plasmafilters. The performance characteristics specified in 4.3 shall be determined prior to marketing a new type of device and shall be re-evaluated after changes in the device that might alter its performance. The sample of device shall be drawn at random from the manufacturer’s production and shall have passed all applicable quality control steps, as well as sterilization. They shall be prepared according to the manufacturer’s recommendations as though they are to be used for a clinical procedure Measurements shall be made in vitro at (37 ± 1) °C. When the relationship between variables is nonlinear, sufficient determinations shall be made to permit interpolation between the data points. The techniques of measurement given in this document are reference tests. Other test methods may be used, provided they have been validated and shown to be precise and reproducible. The test systems shown do not indicate all the necessary details of practicable test apparatus. The design and construction of actual test systems and the establishment of actual test systems shall also address the many factors contributing to measurement error, including, but not limited to, pressure measurement errors due to static head…

  • ISO 16837-2019 pdf free.Non-destructive testing一Acoustic emission testing- Test method for damage qualification of reinforced concrete beams. The internal noise of the amplifier shall be inherently low and less than 20 1.tV (26 dBAE for 0 dBAE = 1 iV) as the peak voltage converted by input voltage. The amplifier shall be also robust enough against the environmental conditions and be protected properly. The frequency range shall be determined prior to the measurement, taking into account the performance of AE sensor and the amplifiers. A suggested range in concrete is from around 10 kFIz to 100 kHz, because such higher frequency components as over 1 MHz readily attenuate in concrete. For signal analysis, AE parameters of AE count or AE hit shall be detected and processed. The measurement system shall be able to obtain time information along with AE data. In addition, such external parameters as load, strain and so forth are preferably recorded in the system, which can be equipped with enough memory to record the data measured. It is preferable that all the data recorded be analyzed digitally by computer. 5 Environmental noises In advance of the AE measurement, the noise level shall be estimated. Then, counteract against external…