ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process.
5 Requirements for assessment body personnel
5.1 General provisions
In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024).
The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality.
Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined competency criteria for the tasks identified. They shall be trained for their specific responsibilities within the assessment body and shall be made aware of the significance of the certification or recognition offered.
The assessment body shall establish and maintain up-to-date documentation on the qualification, training and experience relevant to the assessment activity of each individual. This information shall be accessible to the individual(s) concerned and shall include the following:
a) name and address;
b) organization affiliation and position held:
C) educational qualifications and professional status;
d) experience and training in each field of the assessment body’s competence;
e) their specific responsibilities and obligations within the assessment body:
t) performance appraisals:
g) date of most recent updating of records.
5.2 Additional criteria for examiners
Examiners shall meet the requirements of the assessment body. based upon applicable standards and normative documents.
When selecting examiners for a specific examination or part of one, the assessment body shall ensure that the competence brought to each assignment is sufficient. Examiners shall:
a) be familiar with the relevant assessment system;
b) have a thorough knowledge of the relevant examination methods and examination documents:
c) have appropriate technical knowledge of the activities which are to be examined;
d) be able to communicate effectively, both in writing and orally (through an interpreter if necessary), in the language of the examination:
e) be free from any conflicting interests so that they can make impartial and non-discriminatory assessments.
Provisions shall be made by the assessment body to ensure that the examination is not compromised. If conditions exist which force the participation of the trainer or instructor in the testing of the candidates trained or instructed by him or her, the instructor, who acts as an invigilator. shall not have access to the examination.ISO 18436-1 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 5838-1-2013 pdf free.Implants for surgery- Metallic skeletal pins and wires – Part 1: General requirements. This part of ISO 5838 specifies general requirements for metallic skeletal pins and wires for use in bone surgery, excluding wires for binding and twisting. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3651-2, Determination of resistance to intergranular corrosion of stainless steels — Part 2: Ferritic,austenitic and ferritic-austenitic (duplex) stainless steels — Corrosion test in media containing sulfuric acid ISO 5832-1, Implants for surgery — Metallic materials — Part 1: Wrought stainless steel ISO 5832-2, Implants for surgery — Metallic materials — Part 2: Unalloyed titanium ISO 5832-3, Implants for surgery — Metallic materials — Part 3: Wrought titanium 6-aluminium 4-vanadium alloy ISO 5832-5, Implants for surgery — Metallic materials — Part 5: Wrought cobalt-chromium-tungsten-nickel alloy ISO 5832-6, Implants for surgery — Metallic materials — Part 6: Wrought cobalt-nickel-chromium- molybdenum alloy ISO 5832-7, implants for surgery — Metallic materials — Part 7; Forgeable and cold-formed…