Standards Download Free
BS pdf,ASME pdf,ISO pdf,ASTM pdf,AS pdf,GB pdf
ISO 16837-2019 pdf free
HomeISO StandardsISO 16837-2019 pdf free
DESCRIPTION

ISO 16837-2019 pdf free.Non-destructive testing一Acoustic emission testing- Test method for damage qualification of reinforced concrete beams.
The internal noise of the amplifier shall be inherently low and less than 20 1.tV (26 dBAE for 0 dBAE = 1 iV) as the peak voltage converted by input voltage. The amplifier shall be also robust enough against the environmental conditions and be protected properly.
The frequency range shall be determined prior to the measurement, taking into account the performance of AE sensor and the amplifiers. A suggested range in concrete is from around 10 kFIz to 100 kHz, because such higher frequency components as over 1 MHz readily attenuate in concrete.
For signal analysis, AE parameters of AE count or AE hit shall be detected and processed. The measurement system shall be able to obtain time information along with AE data. In addition, such external parameters as load, strain and so forth are preferably recorded in the system, which can be equipped with enough memory to record the data measured. It is preferable that all the data recorded be analyzed digitally by computer.
5 Environmental noises
In advance of the AE measurement, the noise level shall be estimated. Then, counteract against external noises, wind, rain, sunshine and so forth shall be conducted to decrease the noise level as low as possible. In the case that the noises have similar frequency contents, amplitudes to AE signals or sources of the noises are unknown, characteristics of the noises shall be estimated prior to the measurement. Based on this result, separation of AE signals from the noises shall be achieved. In this respect, the use of filters is applicable after determining the proper frequency range. Normally, to eliminate mechanical noises due to vibrations, traffics and so forth, a high-pass filter over several kHz is useful. Elimination of electrical noises is made by a low-pass filter over around 100 kHz.
6 Test procedure
6.1 Basics
The period of the measurement shall be prescribed, depending on the conditions of a target structure or member, possibly in service. The sensitivity of the AE measurement system shall be checked routinely by employing the standard source. The variation within the channels shall be lower than ±3 dBAE. The threshold level for counting shall be set as low as possible, depending on the level of the noises.
AE activity is evaluated from the number of AE counts or hits. The onset of AE activity is identified at the time when AE hits of peak amplitude with S dBAE above the threshold are continuously observed under loading.
6.2 Failure modes of reinforced concrete beams and AE activity
Two failure modes are known. One is the bending-mode failure. In the beginning of loading, tensile cracks are nucleated at the bottom of a moment span due to bending moment. When the beam is either under-reinforced for bending or fully reinforced against diagonal shear failure, steel reinforcement in the axial direction yields and tensile cracks are further nucleated and then propagate upward. AE counts or hits in a beam of the bending-mode failure increases acceleratedly with the increase in loading. The other is called the shear-mode failure. In the case that the beam is over-reinforced or little reinforced against diagonal shear failure, final failure results from the sudden generation of diagonal shear cracks in the shear span without yielding of reinforcement.
AE counts or hits are observed at a constant rate because the reinforcement withstands until the final failure. Right before the final stage, diagonal shear cracks arc observed without any precursors along with the rapid increase in AE counts or hits. Since AE activity in a damaged beam is of main concern to apply the recommended practice, these two failure modes should be taken into consideration in the case of AE monitoring.
With respect to AE activity in the reinforced concrete beam, a relation between crack-mouth opening displacement (CMOD) and the presence of the Kaiser effect is known. The Kaiser effect disappears in the case that either the values of CMOD due to bending-mode failure become wider than 0,1 mm and 0,2 mm, or the shear-mode failure is observed. It is noted that the values of CMOD over 0,1 mm approximately correspond to the serviceability limit of the reinforced concrete beam.ISO 16837 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…