-
ISO 283-2015 pdf free.Textile conveyor belts一Full thickness tensile strength, elongation at break and elongation at the reference load – Test method. ISO 283 specifies a test method for the determination of the full thickness tensile strength in the longitudinal direction and the elongation at the reference force and breaking point of conveyor belts having a textile carcass. The method can also be used for the determination of full thickness tensile strength in the transverse direction and the elongation at the breaking point, for use when the manufacturer is requested by the purchaser to state values for these properties. This International Standard is not suitable or valid for light conveyor belts as described in ISO 2 1183-1. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 7500—1, Metallic materials — Verification of static uniaxial testing machines — Part 1: Tension/compression testing machines — Verfication and calibration of the force-measuring system ISO 18573, Conveyor belts — Test atmospheres and conditioning periods 3 Terms and definitions…
-
ISO GUIDE 30-2015 pdf free.Reference materials – Selected terms and definitions. This Guide recommends terms and definitions that should be used in connection with reference materials, with a particular emphasis on terms that are used in reference material product information sheets, certificates and corresponding certification reports. 2 Terms and definitions 2.1 Terms related to materials 2.1.1 reference material RM material, sufficiently homogeneous and stable with respect to one or more specified properties, which has been established to be fit for its intended use in a measurement process Note I to entry: RM is a generic term. Note 2 to entry: Properties can be quantitative or qualitative. e.g. identity of substances or species. Note 3 to entry: Uses may include the calibration of a measurement system, assessment of a measurement procedure, assigning values to other materials, and quality control. Note 4 to entry: ISO/I EC Guide 99:2007111 has an analogous definition (5.13), but restricts the term “measurement” to apply to quantitative values. However, Note 3 of ISO/IEC Guide 99:2007, 5.13 (VIM), specifically includes qualitative properties, called nominal properties”. 2.1.2 certified reference material CRM reference material (RM) characterized by a metrologically valid procedure for one or more specified properties, accompanied by an…
-
ISO 16610-22-2015 pdf free.Geometrical product specifications (GPS) – Filtration 一 Part 22: Linear profile filters: Spline filters. This part of Iso 16610 specifies spline filters for the filtration of profiles. It specifies in particular how to separate the long- and short-wave component of a profile. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 16610-1:2015, Geometrical product specifications (GPS) — Filtration — Part 1: Overview and basic terminology ISO 16610-20:2015, Geometrical product specifications (GPS) — Filtration — Part 20: Linear profile filters: Basic concepts ISO/IEC Guide 99:2007, lnternational vocabulary of metrology — Basic and general concepts and associated terms (VIM) ISO/IEC Guide 98-3:2008, Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO/IEC Guide 99:2007 (VIM), ISO 16610-1, and ISO 16610-20 and the following apply. 3.1 spline linear combination of piecewise polynomials, with a smooth fit between the pieces Note ito…
-
ISO 10816-21-2015 pdf free.Mechanical vibration – Evaluation of machine vibration by measurements on non-rotating parts – Part 21:Horizontal axis wind turbines with gearbox. This part of Iso 10816 specifies the measurement and evaluation of mechanical vibration of wind turbines and their components by taking measurements on non-rotating parts. It applies to horizontal axis wind turbines with mechanical gearbox and rated generator output exceeding 200 kW and the following design and operational characteristics: a) installation on supporting systems (tower and foundation) made of steel and/or concrete; b) horizontal axis rotor with several rotor blades; c) rotor bearing separate from or integrated into the gearbox; d) generators driven via gearbox; e) generators of the synchronous or asynchronous type (mostly equipped with 4-pole generator); f) generators with only a fixed pole number or which are pole-changeable for speed adjustment; g) output control by rotor blades (pitch or stall wind turbines); h) generator coupled to the power grid via converter or directly. This part of ISO 10816 recommends zones for evaluating the vibration at continuous load operation. However, in most cases, these evaluation zone boundaries might not be suitable for the early detection of faults. This part of ISO 10816 does not specify vibration…
-
ISO 17634-2015 pdf free.Welding consumables – Tubular cored electrodes for gas shielded metal arc welding of creep-resisting steels – Classification. ISO 17634 specifies requirements for classification of tubular cored electrodes used in the post-weld heat-treated condition for gas shielded metal arc welding of creep-resisting and low alloy elevated temperature steels. One tubular cored electrode can be tested and classified with different shielding gases. This International Standard is a combined specification providing for classification utilizing a system based upon the chemical composition of all-weld metal or utilizing a system based upon the tensile strength and the chemical composition of all-weld metal. 1) Paragraphs and tables which carry the suffix letter are applicable only to tubular cored electrodes classified to the system based upon chemical composition with requirements for the yield strength and the average impact energy of 47 J of all-weld metal in accordance with this International Standard. 2) Paragraphs and tables which carry the suffix letter ‘B are applicable only to tubular cored electrodes classified to the system based upon the tensile strength and chemical composition of all- weld metal in accordance with this International Standard. 3) Paragraphs and tables which have neither the suffix letter A nor the suffix…
-
ISO 8536-11-2015 pdf free.Infusion equipment for medical use 一 Part 11: Infusion filters for single use with pressure infusion equipment. This part of ISO 8536 applies to sterilized infusion filters for single use used up to 200 kPa (2 bar) on fluid lines of pressure infusion equipment and infusion set as specified in ISO 8536-8. It does not include the effectiveness of filters for separation of particles or germs. In some countries, the national pharmacopoeia or other national regulations are legally binding and take precedence over this part of ISO 8536. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 594-2,flConical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment — Part 2: Lock fittings ISO 7000, Graphical symbols for use on equipment — Registered symbols ISO 8536-4:2010, Infusion equipment for medical use — Part 4: Infusion sets for single use, gravity feed ISO 10993-4, Biological evaluation of medical devices — Part 4: Selection of tests for interactions…
-
ISO 3245-2015 pdf free.Rolling bearings一Needle roller bearings with drawn cup and without innerring – – Boundary dimensions, geometrical product specifications [GPS] and tolerance values. ISO 3245 specifies the boundary dimensions and preferred dimensions to be used for drawn cup needle roller bearings without inner ring as well as the minimum chamfer dimension limits. Also specified are the closed end thickness dimensions for hearings with one closed end. In addition, dimensional tolerances for the needle roller complement bore diameter and tolerances for the drawn cup width are specified. Informative values for the tolerances for shaft raceway and housing bore are given in AnnexA. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1132-1, Rolling bearings — Tolerances — Part 1: Terms and definitions ISO 5593, Rolling bearings — Vocabulary ISO 10579, Geometrical product specifications (GPS) — Dimensioning and tolerancing — Non-rigid parts ISO 14405-1, Geometrical product specifications (GPS) — Dimensional tolerancing — Part 1: Linear sizes ISO 15241, Rolling bearings — Symbols for physical…
-
ISO 10976-2015 pdf free.Refrigerated light hydrocarbon fluids一Measurement of cargoes on board LNG carriers. ISO 10976 establishes all of the steps needed to properly measure and account for the quantities of cargoes on liquefied natural gas (LNG) carriers. This includes, but is not limited to. the measurement of liquid volume, vapour volume, temperature and pressure, and accounting for the total quantity of the cargo on board. This International Standard describes the use of common measurement systems used on board LNG carriers, the aim of which is to improve the general knowledge and processes in the measurement of LNG for all parties concerned. This International Standard provides general requirements for those involved in the LNG trade on ships and onshore. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 8310, Refrigerated hydrocarbon and non-petroleum based liquefied gaseous fuels — General requirements for automatic tank thermometers on board marine carriers and floating storage ISO 8943, Refrigerated light hydrocarbon fluids — Sampling of liquefied natural gas —…
-
ISO 9000:2015 pdf free.Quality management systems – Fundamentals and vocabulary. ISO 9000 describes the fundamental concepts and principles of quality management which are universally applicable to the following: • — organizations seeking sustained success through the implementation of a quality management system: • — customers seeking confidence in an organization’s ability to consistently provide products and services conforming to their requirements; • — organizations seeking confidence in their supply chain that product and service requirements will be met; • — organizations and interested parties seeking to improve communication through a common understanding of the vocabulary used in quality management: • — organizations performing conformity assessments against the requirements of ISO 9001; • — providers of training, assessment or advice in quality management; • — developers of related standards. This International Standard specifies the terms and definitions that apply to all quality management and quality management system standards developed by ISOITC 176. Only informative sections of standards are publicly available. To view the full content, you will need to purchase the standard by clicking on the “Buy” button. 3 Terms and definitions 3.1 Terms related to person or people 3.1.1 top management person or group of people who directs and controls…
-
ISO 3826-4-2015 pdf free.Plastics collapsible containers for human blood and blood components – Part 4:Aphaeresis blood bag systems with integrated features. This part of Iso 3826 specifies requirements including performance requirements for aphaeresis blood bag systems with integrated features. Aphaeresis blood bag systems need not contain all of the integrated features identified in this part of ISO 3826. The integrated features refer to: — needle stick protection device; — leucocyte filter; — sterile barrier filter; — pre-coflection sampling device; — red blood cell storage bag; — plasma storage bag; — platelet storage bag; — polymorphonucleic (e.g. stem) cell storage bag; — post-collection sampling devices; and — connections for storage solutions, anticoagulant, and replacement fluid. This part of ISO 3826 specifies additional requirements for blood bag systems used to collect varying quantities of blood components or cells by apheresis. This part of ISO 3826 can be used on automated or semi-automated blood collection systems. In some countries, the national pharmacopoeia or other national regulations are legally binding and take precedence over this part of 150 3826. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated…