DESCRIPTION

ISO/DIS 13715-2014 pdf free.Technical product documentation – Edges of undefined shape – Indication and dimensioning.
ISO/DIS 13715 specifies rules for the indication and dimensioning of undefined edges in technical product documentation.The proportions and dimensions of the graphical symbols to be used are also specified.
NOTE The undefined edge can only he specified in 21) drawings.
In cases where the geometrically defined shape of an edge (for example 1 x 450) is required, the general dimensioning principles given in ISO 129-1 apply.
2 Normative references
The following document, in whole or in part, is normatively referenced in this document and is indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 3098-0:1997, Technical product documentation — Lettering — Part 0: General requirements 3 Terms and definitions
edge of undefined shape
transition line, included in an intersection plane, which is not defined on the nominal model and which exists between two adjacent integral surfaces
burr
roughremainderofmaterialoutsidetheidealgeometrical shapeofanexternaledge,residueofmachiningorofa formingprocess
NOTE 1 Examples arc presented in Figure 1.
NOTE 2 A burr Is an unwanted but often an unavoidable defect.
3.3 undercut
deviation inside the ideal geometrical shape of an edge
NOTE Examples are presented in Figures 2 and 3.
3.4 passing
deviation outside the ideal geometrical shape of an internal edge
4 Indications on drawings
4.1 Basic indication
The requirements for an edge of a part shall be indicated by the basic graphical indication shown in Figure 5. If all edges of a part are to be specified as undefined, the basic general indication is used (Figure 6).
The leader line shall be attached to the left end of the reference line. For angles other than 90%, the leader line shall be parallel to one of the two surfaces (see Figure 7).
The graphical symbol and the specification shall be represented in such a way that they can be read from the bottom of the drawing.
The proportions of this symbol are given in Annex A. Additional indications can be placed in the areas a1, a2 or Q3, see Figure A.1.
An undefined edge can not be described by the basic element alone. At least the shape of the edge must be described.
4.2 Shapeof an undefined edge
The shape of an edge shall be indicated in the area a1(see Figure A.1), inside the basic symbol. The symbol element + (plus), – (minus) or ± (plus or minus) is used in accordance with Table 1.
The symbol element + (plus) indicates permitted excess material in relation to the nominal shape of the edge; burr on external and passing on internal edges.
The symbol element- (minus) indicates required material removal in relation to the nominal shape of the edge; undercut of external and internal edges.
The symbol element± (plus or minus) indicates that excess material or undercut to the given limit is permitted.This can only be used only with an indicaton of size (see 4.4).
The deviation from ideal nominal shape can be controlled by Indicating the size of burr and undercut (see 4.3) and the direction (see 4.4).ISO/DIS 13715 pdf free download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…