BS ISO 6432:2015 pdf free.Pneumatic fluid power一 Single rod cylinders, 1 000 kPa (10 bar) series, bores from 8mmto25mm一Basicand mounting dimensions.
BS ISO 6432 establishes a metric series of mounting dimensions required for interchangeability of commonly used pneumatic cylinders for a maximum working pressure of 1 000 kPa (10 bar).
NOTF This International Standard allows manufacturers freedom of design in metric cylinders and does not restrict technical development but provides basic guidelines.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 3320, Fluid power systems and components — Cylinder bores and piston rod diameters and area ratios — Metric series
ISO 4393, Fluid power systems and components — Cylinders — Basic series of piston strokes
ISO 4395, Fluid power systems and components — Cylinder piston rod end types and dimensions
ISO 5598, Fluid power systems and components — Vocabulary
ISO 6099, Fluid power systems and components — Cylinders — Identification code for mounting dimensions and mounting types
ISO 16030, Pneumatic fluid power — Connections — Ports and stud ends
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 5598 apply.
4 Dimensions
4.1 Basic dimensions
The basic dimensions are given in Table I and shown in Figure 1.
4.2 Mounting dimensions
The mounting dimensions are given in Tables 2 to 5 and shown in Figures 2 to 5.
NOTE 1 The sign + after letters means that the stroke is to be added to the actual dimension.
The tolerances of dimensions dependent on stroke included in the tables apply for strokes up to and including 100 mm. If strokes are longer than 100 mm, tolerances should be selected from national standards or by agreement between the manufacturer and user.
5.1 Select the nominal strokes from the recommended values shown in ISO 4393.
5.2 The nominal stroke tolerance is 1.5 mm for strokes up to and including 100 mm. If strokes are longer than 100 mm, tolerances should be selected from national standards or by agreement between the manufacturer and user.
6 Bore sizes
Included in this series are the following bore sizes AL, in millimetres, in accordance with ISO 3320:
8-10-12-16—20—25
7 Mounting types
This International Standard includes a combination of the following mounting types as described in
ISO 6099:
— MR3: Head threaded mounting (see Table 4, Figure 4)
— MP3: Cap fixed eye mounting (see Table 3. Figure 3)
— MS3: Head angle mounting (see Table 5, Figure 5)
— MF8: Head rectangular flange (two hole) mounting (see Table2, Figure 2).
8 Piston rod characteristics
This International Standard applies to the following piston rod characteristics:
Shouldered or unshouldered male threads.
The dimensions of the piston rod threads shall be chosen in accordance with ISO 4395.
9 Identification statement (reference to this International Standard)
Use the following statement in test reports, catalogues and sales literature when electing to comply with this International Standard:
“Basic, mounting and accessories dimensions of pneumatic cylinders conform to ISO 6432, Pneumatic fluid power — Single rod cylinders, 1 000 kPa (10 bar) series, bores from 8 mm to 25 mm — Basic and mounting dimensions.”BS ISO 6432 pdf free download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…