Standards Download Free
BS pdf,ASME pdf,ISO pdf,ASTM pdf,AS pdf,GB pdf
ISO 8820-5-2015 pdf free
HomeISO StandardsISO 8820-5-2015 pdf free
DESCRIPTION

ISO 8820-5-2015 pdf free.Road vehicles – Fuse-links – Part 5: Fuse-links with axial terminals (Strip fuse-links) Types SF 30 and SF 51 and test fixtures.
This part of ISO 8820 specifies fuse-links with axial terminals (Strip fuse-links) Type SF 30 and SF 51 and test fixtures for fuses in road vehicles. It establishes, for these fuse-link types, the rated current, test procedures, performance requirements. and dimensions.
This part of ISO 8820 is applicable to fuse-links with a rated voltage of 32 V, a current rating of 30 A to
500 A, and a breaking capacity of 2 000 A intended for use in the electrical system of road vehicles with
a nominal voltage of 12 V and/or 24 V.
This part of ISO 8820 is intended to be used in conjunction with ISO 8820-1 and with ISO 8820-2. The numbering of its Clauses corresponds to that of ISO 8820-1, whose requirements are applicable except where modified by requirements particular to this part of ISO 8820.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 4017, Fasteners — Hexagon head screws — Product gradesA and B
ISO 4032, Hexagon regular nuts (style 1) — Product grades A and B
ISO 7089, Plain washers — Normal series — Product grade A
ISO 8820-1, Road vehicles — Fuse-links — Part 1: Definitions and general test requirements
ISO 8820-2, Road vehicles — Fuse-links — Part 2: User guidelines
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 8820-1 apply.
4 Marking, labelling, and colour coding
The requirements given in Table 1 and ISO 8820-1 shall apply.
5 Tests and requirements
5.1 General
5.1.1 General test conditions
In addition to carrying out the test procedures in accordance with Iso 8820-1, the following criteria shall apply:
— tests shall he performed following the test sequences in Table 2:
— the test fixtures for electrical tests shall be designed in accordance with Figure 4 to Figure 7. The connection resistance shall be a maximum of 1,0 mci for SF 30 fuse-links and a maximum of 0,35 mci for SF 51 fuse-links to ensure the proper function of the test fixture;
— terminals shall have a suitable finish which will ensure corrosion protection and shall have satisfactory mechanical and electrical properties.
Fuse-link type SF 30 with a rated current of 150 A…200 A and fuse-link type SF 51 with a rated current of 300 A … 500 A shall only be used for short circuit protection and have to be tested with a cable, the insulation of which will withstand the test without deterioration.ISO 8820-5 pdf free download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…