ISO 5011-2014 pdf free.Inlet air cleaning equipment for internal combustion engines and compressors – Performance testing.
ISO 5011 establishes and specifies uniform test procedures, conditions, equipment, and a performance report to permit the direct laboratory performance comparison of air cleaners.
The basic performance characteristics of greatest interest are air flow restriction or differential pressure, dust collection efficiency, dust capacity, and oil carry-over on oil bath air cleaners. This test code therefore deals with the measurement of these parameters.
This International Standard is applicable to air cleaners used on internal combustion engines and compressors generally used in automotive and industrial applications.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 5167-1, Measurement of fluid flow by means of pressure differential devices inserted in circular cross- section conduits running full — Part 1: General principles and requirements
ISO 12103-1, Road vehicles — Test contaminants forfilter evaluation — Part 1: Arizona test dust
3 Terms and definitions
3.1 Terms, definitions, symbols and units
For the purposes of this International Standard, the following terms and definitions apply.
3.1.1 air filter air cleaner
device which removes particles suspended in the fresh charge as it is drawn into the engine
3.1.2 filter element
replaceable part of the air filter, consisting of the filter material and carrying frame
3.1.3 secondary element
air cleaner element fitted downstream of the primary element for the purpose of providing the engine with protection against dust in the event of
a) certain types of primary element failure, or
b) dust being present during the removal of the primary element for servicing
4 Measurement accuracy and standard conditions
4.1 Measurement accuracy
Measure the air flow rate to within ± 2 % of the actual value, except for the variable air flow test when accuracy may be ± 2 % of the maximum value of the cyclic flow rate through the cleaner.
Measure the differential pressure and restriction to within 25 Pa of the actual value.
Measure the temperature to within 0.5 °C of the actual value.
Measure the mass to within 1 % of the actual value except where noted.
Measure the relative humidity (RH) with an accuracy oft 2 % RH.
Measure the barometric pressure to within 3 hPa.
The measurement equipment shall be calibrated at regular intervals to ensure the required accuracy.
4.2 Standard conditions
All airflow measurements shall be corrected to a standard condition of 20 °C at 1 013 hPa (1 013 mbar).
See AnnxG.
5 Test materials and test conditions
5.1 Test dust
5.1.1 Grade
The test dust to he used shall be ISO 12103 – A2 (ISO Fine) or ISO 12103 – A4 (ISO Coarse), subject to agreement between the filter manufacturer and client. The chemical analysis and the particle size distribution shall conform to ISO 12103-1.
In the absence of an agreement on the dust
— for single-stage filters, use ISO Fine test dust, and
— for multistage filters, use ISO Coarse test dust.ISO 5011 pdf free download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…