ISO 27668-1-2016 pdf free.Gel ink ball pens and refills一Part 1: General use.
This part of Iso 27668 establishes minimum quality requirements for gel ink ball pens (refillable and non-refillable) and refills for general use.
Additional requirements for gel ink ball pens for documentary use are given in ISO 27668-2.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 1O5-A02, Textiles — Tests for colourfastness — Part A02: Grey scale for assessing change in colour ISO 105-B02, Textiles — Tests for colourfastness — Part B02: Colourfastness to artificial light: Xenon arc fading lamp test
ISO 534, Paper and board — Determination of thickness, density and specific volume ISO 535, Paper and board — Determination of water absorptiveness — Cobb method ISO 536, Paper and board — Determination ofgrammage
ISO 868, Plastics and ebonite — Determination of indentation hardness by means of a durometer (Shore hardness)
ISO 2144, Paper, board and pulps — Determination of residue (ash) on ignition at 900 degrees C
ISO 5627, Paper and board — Determination of smoothness (Bekk method)
ISO 6588-1, Paper, board and puips — Determination of pH of aqueous extracts — Part 1: Cold extraction
ISO 6588-2, Paper, board and pulps — Determination of pH of aqueous extracts — Part 2: Hot extraction
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1 pen writing instrument equipped with a feeding system which deposits a writing fluid on a surface
Note 1 to entry: It is available in refillable or non-refillable (disposable) form.
3.2 ball pen pen with a writing fluid feeding system based on a rotatable ball writing tip integrated either within
the pen itself or within a refill.
3.3 gel ink ball pen ball pen which deposits a writing fluid whose viscosity decreases markedly with rotation of the ball when writing and increases back to or near to the original viscosity in non-movement, i.e. when not writing
3.4 cartridge disposable container for the writing fluid, which is detached when empty and replaced by a (new) full container
Note ito entry: Adapted from ISO 9175-1:1988, 3.4.
3.5 refill identifiable assembly of components, usually removable from a complete pen. with which it is possible to write independently of the complete pen, but which lacks either characteristics or components which would make it suitable for use as a pen.
3.6 write test machine device for mechanically generating a line with a pen or refill on a writing surface and which can be adjusted for
— a writing angle between 60° and 90°,
— writing load from 0,1 N to 5 N,
— writing speed between 1 rn/rn in and 10 rn/mm, and
— line pitch between 1 mm and 5 mm,
with a continuous spiral line (100 mm circumference) and a fixed or rotating motion along the longitudinal axis of the pen or refill; the writing surface is to be placed on a polished stainless steel plate. [SOURCE: ISO 12756:1998, 3.7].ISO 27668-1 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…