ISO 178-2019 pdf free
HomeISO StandardsISO 178-2019 pdf free
DESCRIPTION

ISO 178-2019 pdf free.Plastics一Determination of flexural properties.
A test specimen of rectangular cross-section, resting on two supports, is deflected by means of a
loading edge acting on the specimen midway between the supports. The test specimen is deflected in
this way at a constant rate at midspan until rupture occurs at the outer surface of the specimen or until
a maximum strain of 5 % (see 3) is reached, whichever occurs first. During this procedure, the force
applied to the specimen and the resulting deflection of the specimen at midspan are measured.
This document specifies two methods: method A and method B. Method A uses a strain rate of
1 %/min throughout the test. Method B uses two different strain rates: 1 %/min for the determination of the flexural modulus and 5 %/min or 50 %/min, depending on the ductility of the material, for the
determination of the remainder of the flexural stress-strain curve.
NOTE 1 The strain rates mentioned above are to be interpreted as nominal ones. Nominal test speeds are calculated using Formula (4). For the machine settings the best fitting ones are selected from Table 1.
NOTE 2 For materials exhibiting nonlinear stress/strain behaviour, the flexural properties are only nominal. The formulae given have been derived assuming linear elastic behaviour and are valid for deflections of the specimen that are small compared to its thickness. With the preferred specimen (which measures 80 mm x 10 mm x 4 mm) at the conventional flexural strain of 3,5 % and a span-to-thickness ratio, L/h, of 16, the deflection is 1,5h. Flexural tests are more appropriate for stiff and brittle materials showing small deflections at break than for very soft and ductile ones.
5 Test machine
5.1 General
The machine shall comply with ISO 7500-1 and ISO 9513 and the requirements given in 5.2 to SA.
Flexural tests, according to the specific requirements on the data to be obtained, can be differentiated in several classes, comprising different complexity and requirements on accuracy. This starts with simple tests for obtaining flexural strength only on the one hand and on the other hand necessitates the use of a deflectometer to obtain the deflection accurately and free of compliance effects of the machine. The compliance of flexural testing machines has several possible sources (play and deformations in fixtures, deformations in the load train, and deformations of the load cell). Precise and true determination of deflection is especially important for the determination of the flexural modulus, for which the use of uncorrected crosshead displacement is not suitable. For a repeatable determination of flexural modulus results a compliance correction shall be applied or, preferably, a deflectometer shall be used.
5.4.2 Definition of precision and accuracy requirements
Table 2 defines objectives of testing in increasing order of test complexity and appertaining need for accuracy. A good precision without absolute accuracy as indicated in type Ill-tests can be sufficient in many quality control environments when properties are to be supervised over periods of time only. Accurate, meaning true and precise, results as indicated in type IV-tests are needed if the results are to be compared between laboratories. Different types of deflection measurement and different accuracy requirements for the deflection measurement are therefore defined, based on the needs on precision
and trueness of the test results.ISO 178 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…