ISO 16525-2-2014 pdf download.Adhesives一Test methods for isotropic electrically conductive adhesives – Part 2: Determination of electrical characteristics for use in electronic assemblies.
This part of Iso 16525 specifies test methods for isotropic electrically conductive adhesives used in wiring, die attach, and surface assembly of printed circuit boards of electronic devices. The test methods focus on volume and interfacial contact resistivity.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, oniy the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
Iso 472, Plastics — Vocabulary
ISO 554, Standard atmospheres for conditioning and/or testing — Specifications
ISO 80000-1, Quantities and units — Part 1: General
IEC 60468, Method of measurement of resistivity of metallic materials
IEC 61249-2-7, Materials for printed boards and other interconnecting structures – Part2-7: Reinforced base materials clad and unclad – Epoxide woven E-glass laminated sheet of defined flammability (vertical burning test), copper-clad
EN 923, Adhesives — Terms and definitions
ASTM B539-02, Standard Test Met hods for Measuring Resistance of Electrical Connections (Static Contacts)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 472, ASTM B539-02 and EN 923 and the following apply.
3.1 isotropic electrically conductive adhesive
<electronic assembly> resin that contains fillers, which provide electrical conduction, and functions as an adhesive
3.2 volume resistivity
electrical resistance of the isotropic electrically conductive adhesive for a given cross-sectional area or given length
Note 1 to entry: Electrical volume resistivity is converted to resistance per given cross-sectional area or given length of the isotropic electrically conductive adhesive. This part of ISO 16525 specifies measurement methods for an isotropic electrically conductive adhesive, which is applied to a circuit board that is similar to the one used in practice.
Note 2 to entry: It is expressed as ohm metre (Q.m).
3.3 interfacial contact resistivity
electrical resistance that is generated on the contactsurface between the isotropic electrically conductive adhesive and the adherend
Note 1 to entry: It is expressed as electrical resistance per given cross-sectional area (2-m2).
Note 2 to entry: Interfacial contact resistance is generated on the contact surface between the isotropic electrically conductive adhesive and the electrode, and it is thought to be associated with the dispersion of the metal component in the vicinity of the electrode interface, oxide film, and the arrangement of conductive particles contained in the isotropic electrically conductive adhesive. In addition, interfacial contact resistivity fluctuates during the endurance test. Apart from the resistance component brought by electrically volume resistivity of the isotropic electrically conductive adhesive, if a resistance component is placed on the contact surface, interfacial resistance is expressed by resistivity per given area and is converted to resistance per given cross-sectional area or length of the isotropic electrically conductive adhesive.ISO 16525-2 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…