ISO 10113-2020 pdf free.Metallic materials –  Sheet and strip – Determination of plastic strain ratio.
The law of constancy of volume is only applicable up to the percentage of plastic extension at maximum force, Ag because after this point local necking starts and the used mathematical approaches are no longer valid.
Several materials clearly show a slight local necking before A . This can lead to higher instantaneous width reduction values and results in higher r-values, especialy when an extensometer is used which measures the instantaneous width reduction only in the central region of the gauge length. In these cases, the following points are recommended:
a) extensometers for measurement of the instantaneous width reduction which are able to measure the change of width in multiple locations ideally evenly distributed across the entire gauge length (see Clause 6) should be used;
b) the parallel length of the test piece should be minimum six times of the original gauge width of the test piece b0.
The orientation of the test piece relative to the rolling direction, and the plastic (engineering) strain for which the values of r are determined, are as specified in the relevant product standards.
An r-value greater than one describes a behaviour where the material deforms more in the width than in the thickness ( b> p a see Figure 1). An r-value lower than one describes a behaviour where the material deforms more in the thickness than in the width ( b < a see Figure 1). An r-value of one describes an isotropic forming behaviour in width and thickniss (i = epa; see Figure 1).The tensile testing machine used shall comply with the requirements of ISO 6892-1.
For the manual method (see &Z) the device for the measurement of the original gauge length and the gauge length after plastic straining and unloading shall be capable of measuring with an accuracy of ±0,2 % or better. The device used for determining the original width and the gauge width of the test piece after plastic straining and unloading shall be capable of measuring with an accuracy of ±0,005 mm or better.
For the semi-automatic method (see B.13), an extensometer for length measurement in accordance with ISO 9513, of class 1 or better, shall be used. The device used for determining the original width and the gauge width of the test piece after plastic straining and unloading shall be capable of measuring with an accuracy of ±0,005 mm or better.
For the automatic method (see 4), extensometers in accordance with ISO 9513, of class 1 or better in the relevant strain range, shall be used. The device used for determining the original width shall be capable of measuring with an accuracy of ±0,1 % or better.
NOTE When using a long gauge length and large extensions are applied, the maximum error of the class 1 extensometer can be greater than ±0,0 1 mm.
The method of gripping the test piece shall be as specified in ISO 6892-1.ISO 10113 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…