Standards Download Free
BS pdf,ASME pdf,ISO pdf,ASTM pdf,AS pdf,GB pdf
DIN EN ISO 844:2014 pdf free
HomeISO StandardsDIN EN ISO 844:2014 pdf free
DESCRIPTION

DIN EN ISO 844:2014 pdf free.Rigid cellular plastics -Determination of compression properties (ISO 844:2014); ;English version EN ISO 844:2014,English translation of DIN EN ISo 844:2014-11.
A force sensor shall be fixed to one of the machine plates in order to measure the force F produced by the reaction of the test specimen upon the plates during the test. This sensor shall be such that its own deformation during the course of the measurement operation is negligible compared with that being measured and, in addition, it shall allow the continuous measurement of the force at any point in time with an accuracy of ± 1 %.
Itis recommended that a device he used for the simultaneous recording of the force Fand the displacement x that allows, by obtaining a curve of F = 1(x), the graphical determination of the pair of values F; x required In Clause 9 with the accuracy laid down in 6.2.1 and this subclause, and provides additional information on the behaviour of the product.
6.2.3 Calibration
Devices for measuring and, if applicable, recording graphically the force and displacement produced by the test machine shall he checked periodically. The devices shall he checked by using a series of standard weights, the masses of which are known to accuracies better than ± I % and which correspond to the forces applied during the test. To check the devices, spacers shall be used which have thicknesses known to accuracies better than either ± 0,5 % or ± 0,1 mm, whichever is more restrictive.
6.3 Instruments for measuring the dimensions of the test specimens These instruments shall be in accordance with ISO 1923.
7 Test specimens
7.1 Dimensions
The test specimens shall be (50 ± 1) mm in thickness except for products with moulded skins which are intended to remain integral with the product in use. With such products, the specimens shall be the full thickness, provided that the minimum thickness Is 10 mm or greater and that the maximum thickness Is not greater than the width or diameter of the specimen.
The test specimen base shall be either square or circular, with a minimum area of 25 cm2 and maximum of 230 cm2. The preferred geometry and dimensions are a right prism with a base of (100 ± 1) mm x (100 ± 1) mm.
The distance between two faces shall not vary by more than 1 % (tolerance on parallelism).
Under no circumstances may several test specimens be piled up to produce a greater thickness for testing.DIN EN ISO 844 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…