BS ISO 9642:2020 pdf free.Cinematography一Time and control code for 24, 25 and 30 frames per second motion-picture film systems – Specifications.
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
lSO/IEC 2022. Information technology — Character code structure and extension techniques
ISO 4241. Cinematography — Projection film leader (time-based), trailer and cue marks — Specifications ISO 8758, Cinematography — Photographic control and data records on 16 mm and 35 mm motion-picture film and prints — Dimensions and location
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:Jjwwwiso.org/obp
— IEC Electropedia: available at http://www.electroptdLurg/
3.1 real time <NTSC colour recording> time elapsed during the scanning of 60 fields (or any multiple thereof) in an ideal television system at a vertical field rate of exactly 60 fields per second
3.2 colour time <NTSC colour recording> time elapsed during the scanning of 60 fields (or any multiple thereof) in a colour television system at a vertical field rate of approximately 59,94 fields per second.
5.2 Type 8 code format
5.2.1 Each motion-picture frame shall be identified by a unique and complete address.
5.2.2 The frames shall be numbered successively 0 to 23, 24 or 29 inclusive, corresponding to the frame rate being used.
5.2.3 Each address shall consist of 112 bits numbered 0 to 111 inclusive.
5.2.4 The bits shall be assigned as shown in the appropriate columns of Figure 1 and in Table 1.
5.2.5 The block of data for a single frame may be recorded anywhere within that frame except that no part of the block may occupy the region extending from the frameline to 5 % of a frame length on either side of it. This region is thus a gap in the data which has a minimum length of 10 % of a frame length. See Figure 3.
5.2.6 The length of any one bit shall not differ by more than 5 % from the length of either adjacent bit. In addition, the length of no bit shall be so short as to make the recording and reproduction of that data, using practical equipment, unreliable. The length of no series of bits shall cause the total length of 112 bits to exceed 90 % of frame length.
5.2.7 In order to reduce the d.c. content of the signal, a repetitive pattern of zeros and ones shall be recorded in as much of the gap area (the frameline region defined in 5.2.5) as is practical. This region shall not contain a sync word of the previous frame or the first sync word of the following frame and shall not be decodable as a valid time code word. The bit length tolerance in 5.2.6 does not apply to data in the gap.
5.3 Use of binary groups
5.3.1 The binary groups are intended for storage of data by the users and the 32 bits within the 8 groups may be assigned in any fashion without restrictions if the character set used for the data insertion is not specified and the binary group flag bits, Nos. 43 and 59, are both zero.BS ISO 9642 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…