BS ISO 16332:2018 pdf free.Diesel engines – Fuel filters – Method for evaluating fuel/water separation efficiency.
As commercially available.
For biodiesel and biodiesel containing fuels the direct Karl Fischer method Is recommended.
Humidity is probably the largest source of error during the titration process. Special precautions shall be taken during setup and testing. The amount of water per sample should be S0 tg to reach a good relation between titration time and accuracy.
5.2.3.2 Centrifuge
For higher water concentration as specified in 6.4.1. 20 000 ppm water concentration, a centrifuge according to can be used. The measurement accuracy according to Table 1 shall be confirmed.
5.2.4 Equipment for determination of IFT
The equipment for determination of the interfacial tension shall be according to ISO 9101.
5.3 Test stand
5.3.1 General
The test stand, shown diagrammatically In Figure 2. shall comprise a fuel/water separator test circuit as described in LiZ.
All parts in contact with fuel, should be made of stainless steel.
5.3.2 Fuel/water separator test circuit
5.3.2.1 Fuel sump (1)
The container with a conical bottom should be made of stainless steel. The fuel outlet shall be located at the lowest point of bottom. The container shall be able to contain the volume as specified in 1. The fuel sump shall be covered with a non-transparent cover to protect the fuel from light. The fuel sump shall contain a suitable device to maintain homogeneity of its content.
5.3.2.2 Water sump (6)
The container should be made of stainless steel or corrosion resistant material with appropriate volume.
NOTE Instead of the container, a continuous water supply unit can be used.
The heat exchanger shall be able to maintain the test fuel temperature T within the tolerances given in Table 1.
Alternative to the position of the heat exchanger depicted in Figurel. the heat exchanger can as well be positioned downstream the back pressure gauge (16).
5.3.2.4 Test pump (2)
A pump type shall be chosen, which does not exhibit pressure pulsation with an amplitude greater than
10 % of the average pressure at the inlet of the water emulsifying device.
5.3.2.5 Water injection pump (7)
The pump type shall be adjustable to enable a water concentration in the test circuit between 1 500 ppm and 20 000 ppm over the complete flow rate of test fluid.
5.3.2.6 Fuel flow meter(5a)
The equipment shall be suitable for the complete range of the flow rate of test fluid with an accuracy as specified in Table 1.
5.3.2.7 Water flow meter (Sb)
The equipment shall be suitable for the complete range of the required injection range with an accuracy as specified in Table 1.
5.3.2.8 Injection device (8)
The concept shall allow a continuous water injection. The resulting DSD at the injection point shall be validated. The validation criterion is defined by:
d3,50 shall be greater or equal to the d3,50 value chosen according to Z
5.3.2.9 Water emulsifying devIce (9)
The concept shall be able to generate a DSD as specified according to Jet emulsification – as described in Annex B is recommended to be applied.
For each combination of emulsifying device, test fuel, flow rate and temperature a calibration curve is mandatory
In case the jet emulsification concept in accordance with Annex B is used, the calibration procedure is described in 4.BS ISO 16332 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…