BS EN ISO 2307:2010 pdf free download.Fibre ropes – Determination of certain physical and mechanical properties (ISO 2307:2010).
The linear density, lay length and braided pitch are measured with the rope under a specified tension called the reference tension, as specified in Annex A.
The elongation corresponds to the measured increase in length of the rope when the tension to which it is subjected is increased from an initial value (reference tension) to a value equal to 50 % of the minimum specified breaking strength of the rope.
The breaking force is the maximum force registered (or reached) during a breaking test on the test piece, carried out on a tensile testing machine with constant rate of traverse of the moving element. The breaking force values given in the tables of rope specifications are only valid when this type of testing machine is used.
When it is not possible to test the whole section of rope, the method described in Annex B can be used, subject to agreement between the parties involved.
This International Standard also provides a method for measuring water repellency, lubrication and finish content, and heat setting treatment, when requested by the customer.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
7.2 Number of test pieces
Take one test piece from each sample.
7.3 Taking the test pieces
Take the test piece either from one end of the samples, or from the body of the samples if they are intended to be cut. Take all necessary steps to prevent unlaying. If necessary. remove slightly unlaid ends.
8 Conditioning
Ropes shall be tested in the ambient atmosphere, except in cases of dispute, when the test piece shall be
placed in the atmosphere specified in Iso 139 for at least 48 h, immediately prior to testing.
9 Procedure
9.1 General
For the measurement of force-elongation and breaking force, perform the procedures specified in 9.2 to 9.7 sequentially.
For the linear density, perform the procedures specified in 9.8.
9.2 Initial measurements
Lay the test piece out straight on a flat surface by pressing with a slight force of the hand (not exceeding 20 % of the reference tension) (see Annex A).
Make two w’ marks on the test piece, spaced symmetrically with regard to its mid-point, and at a distance apart of 10 that is greater than 400 mm.
In exceptional circumstances, when L <400 mm, 1 and 2 (see 9.4) are measured on a separate test piece, with a minimum length of 400 mm, following the same procedure; the value 12 is obtained by applying the appropriate tension by means of weights and a pulley.BS EN ISO 2307 pdf free download.
Tags: Fibre ropes
-
ISO 8600-1-2013 pdf free download.Endoscopes – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…
-
ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…
-
ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…