DESCRIPTION

BS EN ISO 105-G01:2016 pdf free.Textiles一1 Tests for color fastness Part G01: Colours fastness to nitrogen oxide (ISO 105-G01:2016)
This part of Iso 105 specifies two methods for determining the resistance of the colour of textiles of all kinds and in all forms to the action of nitrogen oxides produced during combustion of gas, coal, oil. etc., and when air is passed over heated filaments.
The two tests differ in severity; one or both of them are used, depending on the result obtained (Z2A).
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO I 05-A02, Textiles — Tests for colourfastness — Part A02: Grey scale for assessing change in colour
ISO 105- F02, Textiles — Tests for colour fastness — Part F02: Specification for cotton and viscose ad] acent fabrics
ISO 139, Textiles — Standard atmospheres for conditioning and testing
ISO 3696, Water for analytical laboratory use — Specification and test methods
3 Principle
Specimens of textiles are exposed to nitrogen oxides in a closed container until either one or three test-control fabrics exposed simultaneously with the test specimens have changed in colour to a predetermined extent. The change in colour of each specimen is assessed with the grey scale.
4.6 Urea solution, containing 10 g/l of urea (NH2CONH2), buffered to pH 7 by the addition of 0,4 g/l of sodium dihydrogen orthophosphate dihydrate (NaH2PO4.2H20) and 2,5 g/l of disodium hydrogen orthophosphate dodecahydrate (Na2HPO4•12H20), and containing 0,1 g/l or less of a rapid-wetting surface-active agent, for example, sodium dioctyl sulfosuccinate.
4.7 Test-control fabric
4.7.1 Test-control fabric dyed with Disperse Violet I
A woven filament acetate is uniformly dyed in an open-width dyeing machine with 0.4 % (on mass of fabric) Cl Disperse Violet 1 (Colour Index, Third Edition) in a dye-bath containing 1 g/l of a dispersing agent at a liquor ratio of 10:1.
The fabric construction has both a taffeta and a satin side; for this test procedure, only the taffeta side will be considered.
The resistance of the test-control fabric to the action of nitric oxide should not be varied between the new lots. The supplier should confirm the performance of the new lot.’)
4.7.2 Test-control fabric dyed with Disperse Blue 56
A woven filament acetate is uniformly dyed in an open-width dyeing machine with 0,8 % (on mass of fabric) CI Disperse Blue 56 (Colour Index, Third Edition) in a dye-bath containing 0,5 mI/I of a dispersing agent at a liquor ratio of 42:1.
The fabric construction has both a taffeta and a satin side; for this test procedure, only the taffeta side will be considered.
The resistance of the test-control fabric to the action of nitric oxide should not be varied between the new lots. The supplier should confirm the performance of the new lot.2)
4.8 Standard of fading
4.8.1 Standard fading fabric for test-control fabric dyed with Disperse Violet 1
The regenerated cellulose woven taffeta is a fabric of similar appearance to the test-control fabric (4.7.1.), dyed to match an average of faded test-control fabric..3)
4.8.2 Standard of fading for test-control fabric dyed with Disperse Blue 56
It is considered that the standard of fading is completed when a faded test-control fabric (4.72) is observed to have a contrast equal to grade 3-4 on the grey scale.BS EN ISO 105-G01 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…