ISO 1887-2014 pdf free
HomeISO StandardsISO 1887-2014 pdf free
DESCRIPTION

ISO 1887-2014 pdf free.Textile glass – Determination of combustible-matter content.
ISO 1887 specifies a method for the determination of the combustible-matter content of products made from textile glass, such as continuous-filament yarns, staple-fibre yarns, rovings, chopped strands, milled fibres, fabrics, chopped-strand and continuous-filament mats, and other glass reinforcements.
2 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
2.1 combustible-matter content
ratio of the mass of material removed on calcination from a dried textile glass product to the mass of the dried product
Note 1 to entry: This ratio is expressed as a percentage in this International Standard. It is equal to the content of size or finish on the textile glass product when the size or finish is completely combustible without significant residue (i.e. primarily organic products).
3 Principle
Test specimens. dried under prescribed conditions, are weighed before and after calcination at a temperature of 625 °C ± 20 °C or, with types of glass which are unstable at this temperature, at a temperature between 500 °C and 600 °C, also kept constant to within 20 °C.
4 Apparatus
4.1 Air-circulation oven, for drying specimens, capable of being maintained at 105 °C ± S °C or the chosen drying temperature and maintained to within ±5 °C (see 3).
4.2 Muffle furnace, capable of being maintained, with a tolerance of ±20 °C, at any desired temperature up to 625 °C, the temperature being measured at the centre of the muffle furnace with the door closed.
4.3 Desiccator, containing a suitable desiccant, for example silica gel, calcium chloride, phosphorous(V) oxide.
4.4 Specimen holder, made from a material stable at the test temperature, allowing the best possible air circulation around the test specimen and designed to prevent loss of material. The holder may be a porcelain crucible, a basket made of stainless-steel gauze, etc.
4.5 Stainless-steel tongs, for handling test specimens and holders.
4.6 Balance, accurate to 0,1 mg.
4.7 Polished-metal templates, for the preparation of test specimens.
4.8 Suitable cutting tool, for cutting mat or fabric, for example a knife, scissors, or a cutting disc.
4.9 Suitable wrap.reel, for taking yarn and roving test specimens.
5 Test specimens
5.1 Selection of test specimens
Unless stated to the contrary in the product specification or by the person requesting the test, the test specimens shall be selected as specified in 511 to SIA.
5.1.1 Yarns and rovings
Table 1 gives the length of yarn to be taken as a function of the linear density of the yarn. The test specimen shall not be unduly compressed, in order to ensure that the air will circulate as freely as possible and that drying and calcination will therefore be complete.ISO 1887 pdf free download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…