Standards Download Free
BS pdf,ASME pdf,ISO pdf,ASTM pdf,AS pdf,GB pdf
PD ISO/TR 18230:2015 pdf free
HomeISO StandardsPD ISO/TR 18230:2015 pdf free
DESCRIPTION

PD ISO/TR 18230:2015 pdf free.Iron ores一Determination of loss on ignition一Nonoxidised ores.
This Technical Report describes a gravimetric method for the determination of the loss in mass of non- oxidized iron ores, when ignited at 1 000 °C.
This method is applicable to a concentration range of a mass fraction of—3,0 % to 7,0% loss on ignition in natural iron ores, iron ore concentrates and agglomerates, and sinters.
The method is not applicable to the following:
a) processed ores containing metallic iron (direct reduced iron);
b) natural or processed ores in which the sulfur content is higher than a mass fraction of 0,2 %; c) internationally traded ores with combined water greater than 2,5 %.
NOTE I Loss on ignition can be used as an estimate ol combined water.
NOTE 2 This method is intended for in-house use and is not intended for referee purposes.
2 Principle
A test portion is heated in a muffle furnace at 1 000 °C for 60 mm and cooled in a desiccator. The decreased mass of the test portion is then measured.
3 Reagents
During the analysis, use only reagents of recognized analytical grade.
3.1 Silica gel, dried at 105 °C for 4 h.
4 Apparatus
Ordinary laboratory apparatus and the following:
4.1 Silica, porcelain or platinum crucibles, 15 ml to 25 ml capacity, with lids.
The crucibles should be pre-conditioned in the muffle furnace at 1 000 °C for 60 mm. Crucibles and lids should be stored in the desiccator 4A) prior to use.
If platinum crucibles used for LOl analysis are to be used for flux fusions, platinum ware should be thoroughly cleaned to prevent cross-contamination.
4.2 Balance, capable of reading to the nearest 0,1 mg at the mass load of the crucible.
4.3 Muffle furnace, capable of maintaining a temperature of 1 000 °C ± 25 °C, with provision for air circulation adequate to prevent water vapour retention.
4.4 Desiccator, of borosilicate glass, 150 mm to 250 mm internal diameter with a vacuum stopcock that will allow the evacuation of air.
The desiccator plate should be metal or ceramic or similar that will not break when in contact with a crucible at 1 000 °C. The rim of the desiccator should be lightly greased with silicon grease or petroleum jelly. 150 g to 200 g of silica gel (11) should be replaced daily.
If platinum crucibles are used, metal desiccator plates should not be used.
5 Sampling and samples
5.1 Laboratory sample
For analysis, use a laboratory sample of —100 pim particle size which has been taken and prepared in accordance with ISO 3082.
5.2 Preparation of test samples
Analyses may be performed using either predried test samples (prepared in accordance with ISO 7764).
6 Procedure
6.1 Number of determinations
Carry out the analysis at least in duplicate, using the procedure given in Annex A, independently, on each test sample.
NOTE The expression “independently means that the second and any subsequent result is not affected by the previous result(s). For this particular analytical method, this condition implies that the repetition of the procedure are to be carried out either by the same operator at a different time, or by a different operator, including appropriate recalibration in either case.
6.2 Test portion
Taking several increments, weigh to the nearest 0,000 1 g, approximately 2,0 g ± 0,2 g of the test sample (2).PD ISO/TR 18230 pdf free download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…