BS ISO 7509:2015 pdf free.Plastics piping systems一 Glass-reinforced thermosetting plastics (GRP) pipes一 Determination of time to failure under sustained internal pressure.
BS ISO 7509 specifies a method for determining the time-to-failure of glass-reinforced thermosetting plastics (GRP) pipes under internal hydrostatic pressure at a specified temperature. The external environment can be air or water.
NOTE Forotherinternal orexternal environments, the referringstandard is to specifyanyadditional requirement.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 3126, Plastics piping systems — Plastics components — Determination of dimensions
ISO 10928, Plastics piping systems — Glass-reinforced thermosetting plastics (GRP) pipes and fittings — Methods for regression analysis and their use
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1 failure occurrence of bursting, leaking, or weeping
Note ito entry: See 2.1.
3.2 bursting failure by rupture of the pipe wall with immediate loss of test liquid and drop of pressure
Note ito entry: See 9.1. and 92.1..
3.3 leaking failure by visible loss of the pressurizing liquid through the pipe wall to an extent detectable visually and/or by a continuous drop in pressure
Note 1 to entry: See 9.1. and 9.L1
3.4 weeping failure by passage of the pressurizing liquid through the pipe wall to an extent detectable visually and/or electronically
Note I to entry: See 2.1 and 9.22.
4 Principle
A cut length of pipe at the required temperature is subjected to a specified internal hydrostatic pressure to cause a state of stress in the pipe wall, which depends upon the loading conditions (i.e. with or without the effects of end thrust being carried by the pipe wall). The results of tests at different end loading conditions will be different even for the same pipe. Water or air may be used as the environment outside of the test piece.
The test samples are held at the test pressure until failure occurs. Typically, the time to failure is longer at lower pressures (stresses).
In general, a series of tests are conducted over various failure times and the results obtained are analysed in accordance with ISO 10928 to establish a long term value. The number of tests required, the appropriate time intervals, and the time at which a value is established (time to failure) are given in the referring standard.
NOTE It is assumed that the following test parameters are set by the standard making reference to this International Standard:
a) whether or not the test piece is to be loaded by the hydrostatic end thrust while under pressure (52);
b) free length, L, of the test piece (see 2);
c) number of test pieces (see 61);
d) test temperature and its tolerance (see BJj;
e) if and what strain measurements are required (see 2);
1) external environmental fluid, i.e. water or air (see 3) or other environment (see Note in Cliuj);
g) internal environmental fluid, if not water or a test liquid for the purposes of 52 and 9.22 (see Note in Clause 1).
5 Apparatus
5.1 DImensional measurement devices, for determining length, diameter, and wall thickness with an accuracy of within ±1,0 %.
52 End sealing devices, for the test piece, capable of inducing the specified state of stress, i.e. with or without hydrostatic end thrust (see Figure 1). The end sealing concepts shown in Figure 1 are only typical and other configurations are possible.BS ISO 7509 pdf free download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…