DESCRIPTION

ISO 7076-6:2016 pdf free download.Fire protection Foam fire extinguishing systems Part 6:Vehicle mounted compressed air foam systems
Protection con tre I’incendie — Systèmes d’extinction d’m centhe ci mousse — Pci, tie 6: Equipemnent pour mousse physique a air corn prime monte stir vehicules.
4.3.2.5 The proportioning ratio shall be automatically maintained within the range —0 % to +30 % of the designated value, even when pressure or rate of compressed air foam may change.
4.3.2.6 At the nominal proportioning ratio, the CAFS shall produce vet foam within the compressed air foam delivery rate limits specified by the manulacturer.
NOTE Another Specific Iequireflient might be agreed between the user and the manufacturer.
4.3.2.7 The foam solution/air volume ratio shall be automatically maintained or easily manually controlled within ±20 % of the designated value as given in the CAFS description [see 7.23 c)J.
4.3.3 Storage vessels
4.3.3.1 Storage vessels shall not leak or become detormed during transport, use, or when being retilled.
4.3.3.2 The quantity of foam concentrate in the storage vessel shall be available to the operator.
5 Tests
5.1 General
5.1.1 Atmospheric conditions for tests
5.1.1.1 unless otherwise stated in a test procedure, conduct the testing after the test specimen has heen allowed to stabilize in the standard atmospheric conditions for testing as specified in IEC 60068-1 as Follows:
— temperature: (15 to 35) °C;
— relative humidity: (25 to 75) %;
— air Iwessure: (86 to 106) kPa.
5.1.1.2 The temperature and humidity shall be substantially constant for each environmental test where the standard atmospheric conditions are applied.
5.1.2 Mounting arrangements
The specimen shall be mounted by its normal means of attachment in accordance with the manufacturer’s instructions. If these instructions describe more than one method of mounting, then the method considered to be most unfavourable shall he chosen for each test.
5.1.3 Operating conditions for tests
5.1.3.1 If a test method requires that a specimen be opei’ational, then the specimen shall be connected to suitable supply and monitoring equipment with characteristics as require(I by the manufacturcrs data. Unless otherwise specified in the test method, the supply parameters applied to the specimen shall be set within the manufacturer’s specified range(s) and shall remain substantially constant throughout the tests. The value chosen for each parameter shall normally be the nominal value or the mean of the SI)CCified range.
5.1.3.2 The details of the supply and monitoring equipment used shall be given in the test report; see Clause 8.ISO 7076-6:2016 pdf free download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…