BS ISO 15363:2017 pdf free.Metallic materials – Tube ring hydraulic pressure test.
When a steel tape is used, friction shall be minimized by coating both the tape and test ring circumference with a suitable lubricant. Change in circumference shall be measured by a suitable mechanical or electrical device accurate to within ± 0,25 mm.
6.3 The equipment for measuring the increase in circumference shall be wrapped around the test ring before application of the internal pressure.
6.4 The tolerance for the measurement of internal pressure shall he within ± I %. Accuracy of the pressure measurement device shall be verified, for example by comparison with dead weight test equipment, at the commencement of a sequence of testing and not less than once per year during the testing period.
6.5 The rate of strain shall not exceed 0,2 % mm-1.
6.6 The pressure and circumferential extension output signals shall be recorded, for example on an X-Y plotter, and related to the test piece identity.
7 Hoop strength evaluation
7.1 A typical test pressure-circumferential extension record is shown in Figure 5.
7.2 The pressure p corresponding to the specified total circumferential strain shall be determined
from the test record.
7.3 For tubes where d/a  20, the hoop strength at the specified total strain shall be calculated from the formula.
For tubes with d/a < 20, the hoop strength calculated from this formula becomes increasingly inaccurate and quantitative results should be used with caution. Factors such as strain hardening could have a significant effect on the validity of the calculated strength.
NOTI€ The specified total circumferential strain is calculated from the circumferential extension divided by the original test ring circumference.
The test report shall contain at least the following information:
a] reference to this document, i.e. ISO 15363;
b) identification of test ring, e.g. cast number/tube number /identification number;
c} material specification, if known;
d] diameter and wall thickness of the tube;
e) length of the tube test ring;
f) calculated hoop strength at specified total circumferential strain;
g) reference to an alternative test method used, when appropriate (see Annex A).BS ISO 15363 pdf free download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…