ISO 20188-2018 pdf free.Space systems—Product assurance requirements for commercial satellites.
5.10 Organizational capability aspects
At least, prime contractor shall be certified to the applicable space standards (e.g. AS 9100, EN 9100 or JIS Q 9100) or equivalent standards. The certificate of registration or a current conformity status relative to the standards will be closely monitored by prime contractor’s PA team.
6 Quality assurance
6.1 Quality assurance program
As part of the PA program, the contractor shall document and maintain an effective and timely quality assurance program in accordance with ISO 27025 or equivalent standards (e.g. Reference [29]). which will be planned in conjunction with other project functions. Quality program shall be implemented in a manner which permits the detection and correction of deficiencies and other associated non. compliances at the earliest practical point. Inclusion of provisions for ascertaining product quality from procurement through fabrication and testing, and the delivery of the completed deliverable system, as well as launch activities, shall be incorporated. Quality assurance program shall provide recorded evidence of quality in the form of inspection and test results as well as systematic audit findings. This record shall be documented in sufficient detail, accuracy and completeness to permit analysis. Records of detected discrepancies shall include root causes and corrective actions implemented as remedy. This record shall be made readily available for review by customer’s representative upon request. Subcontractor quality reports will be reviewed at subcontractor’s sites when not available at contractor’s site.
6.2 Equipment qualification status review
Contractor shall convene equipment qualification status review (EQSR) to verify qualification status of heritage designs with mission requirements. These reviews shall be held at the beginning of the project after categorization of equipment has been determined according to the categories defined in 7J2. The EQSR shall assess qualification status of equipment with particular attention given to any possible design and process changes since the last qualification and to mission-specific requirements. When mutually agreed, the requirement for a unit PDR and/or CDR may be waived by customer in exchange of delivery of a data package and holding an EQSR with mutually acceptable contents. Qualification or proto-f light test reports, and qualification by similarity reports shall be provided to customer in accordance with the applicable SOW.
6.3 Review meeting and control boards
Contractor shall conduct a series of formal technical review meetings and establish control boards to ensure the identification and resolution of issues and verify that appropriate controls are implemented. These meetings shall include reviews and control boards such as design review,Contractor PA shall participate in review meetings and control boards as required to verify appropriate actions have been implemented to satisfy all quality issues and concerns. Control board and review meetings records shall be recorded, signed off and appropriately distributed. The representative of customer shall be invited to participate in all program-specific PA review meetings and control boards in accordance with the applicable Sow.ISO 20188 pdf free download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…