BS ISO 1835:2018 pdf free.Round steel short link chains for lifting purposes一Medium tolerance sling chains – Grade 4, stainless steel.
The bases for calculation of the values for the dimensions listed in Table 1 are given in Annex A.
The bases for calculation of the values for the mass per metre listed in Table B.1 are given in Annex B.
The nominal diameter, dn, of the sling chain corresponds to the nominal diameter of the steel wire as presented in ISO 16124, or bar as presented in ISO 1035-1, from which the sling chain is made.Preferred nominal diameters are given in Table 1 column 1. Other nominal diameters may be used, provided the corresponding dimensions and tolerances are calculated in accordance with Annex A.
The sling chain shall comply with the requirements of ISO 1834 as well as those of this document.
5.2 Material
The steel used shall be austenitic stainless steels with molybdenum and shall be resistant against intergranular corrosion, for example the steel with the ISO name X6CrNiMoTi17-12-2 and the ISO number 4571-316-35-I according to ISO 15510.
After solution annealing intergranular corrosion is unlikely at a service temperature of +400 °C and with an extra low carbon content of the steel. To avoid this corrosive attack under severe service conditions and with higher carbon contents of the steel, a stabilization with titanium Is recommended.
NOTE I The resistance against pitting corrosion can be increased by alloying with molybdenum.
NOTE 2 According to ISO 15510 (see Table A.1), the above-mentioned stainless steel is also well known under the number S31635, where 35 means titanium added. Internationally equivalent numbers of the steel are X6CrNiMoTi17.12.2; 1.4571;AISI/SAE 316Ti and tiNS S31635.
5.3 Heat treatment
All sling chains shall be solution annealed within a temperature range of 1 020 °C to 1 120 °C according to ISO 16143-2 and cooled rapidly by water before being subjected to the manufacturing proof force (MPF).
5.4 Surface condition
For an enhanced corrosion resistance, the sling chains shall be pickled after heat treatment to get a constant smooth surface.
NOTE An improved corrosion resistance and smooth surface condition require the passivation of the surface by pickling after heat treating.
5.5 Dimensions
5.5.1 Diameter The dimensions and tolerances for the diameter, d. shall be as given in Table 1. columns 1 and 2 calculated in accordance with Annex A.
5.5.2 Pitch The dimensions and tolerances for the pitch, p. shall be as given in Table 1. columns 3 and 4 calculated in accordance with Annex A.BS ISO 1835 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…