ISO 29463-2-2011 pdf free download.High-efficiency filters and filter media for removing particles in air – Part 2:Aerosol production, measuring equipment and particle-counting statistics.
This part of ISO 29463 specifies the aerosol production and measuring equipment used for testing high- efficiency filters and filter media in accordance with ISO 29463-3. ISO 29463-4 and ISO 29463-5, as well as the statistical basis for particle counting with a small number of counted events. It is intended to be used in conjunction with ISO 29463-1, ISO 29463-3, ISO 29463-4 and ISO 29463-5.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies,
ISO 29463-1. High-efficiency filters and filter media for removing particles in air — Part 1: Classification, performance, testing and marking
ISO 29463-3. High-efficiency filters and filter media for removing particles in air — Part 3: Testing flat sheet filter media
ISO 29463-4:2011. High-efficiency filters and filter media for removing particles in air — Part 4: Test method for determining the leakage of filter element — Scan method
ISO 29463-5:2011, High-efficiency filters and filter media for removing particles in air — Part 5: Test method for filter elements
ISO 294641), Cleaning equipment for air and other gases — Terminology
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 29463-1. ISO 29464, and the following apply.
3.1 counting efficiency
expression of that proportion of the particles of detectable size suspended in the volume flow under analysis that make their way through the measured volume and are counted by the particle counter
EXAMPLE The ratio of the concentration measured to actual aerosol concentration,
NOTE The counting efficiency depends on the partide size, and decreases progressively in the proximity of the lower detection limit of the particle counter.
4 Aerosol production
When testing a filter, a test aerosol with liquid particles shall be used as reference test method in accordance with ISO 29463-1. Alternatively, a solid PSL aerosol may be used for local efficiency (leak) testing (see ISO 29463-4:2011, Annex E).
The testing of high-performance filters (ISO 65 U and higher) requires methods of aerosol production with high production rates (1010 s 1 to 1011 s 1), in order to provide statistically significant measurements downstream of the filter.
By adjusting the operating parameters of the aerosol generator, it shall be possible to adjust the mean particle diameter of the aerosol so that it is equal to the MPPS. The concentration and the size distribution of the aerosol produced shall remain constant throughout the test.
4.1 Aerosol substances
A suitable aerosol substance for the reference test method is a liquid with a vapour pressure that is so low at the ambient temperature that the size of the droplets produced does not change significantly due to evaporation over the time scale relevant for the test procedure (in the order of a few seconds).ISO 29463-2 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…