ISO 2286-3-2016 pdf free.Rubber- or plastics-coated fabrics – Determination of roll characteristics – Part 3: Method for determination of thickness.
This part of Iso 2286 specifies a method for the determination, at a specified pressure, of the thickness of rubber- and plastics-coated fabrics, irrespective of the type of substrate employed. It is applicable to single-face, double-face and double-texture coated fabrics, as well as materials in which an expanded layer is included in the coating.
2 Normative reference
The following documents, in whole or in part. are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 223 1:1989, Rubber- or plastics-coated fabrics — Standard atmospheres for conditioning and testing
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1 thickness
distance between the face and the back of a coated fabric, measured as the vertical distance between a reference plate on which the fabric rests and a parallel presser foot that is applying a pressure to the fabric
3.2 usable width
width of a coated fabric, excluding the selvedge, which is consistent in its properties, uniformly finished and free from unacceptable flaws
4 Apparatus
4.1 Dial gauge, of the deadweight type, designed to register the vertical distance between the bearing surfaces of a presser foot and reference plate, and equipped with a dial graduated to give a direct readout of the thickness to the nearest 0,01 mm. The gauge shall be calibrated in such a way as to permit at least one of the pressures specified in 4.2 to be obtained using at least one of the presser foot sizes.
4.2 Circular pressure foot, with a smooth, flat surface and a diameter of not less than 9 mm, capable of applying one or more of the following pressures:
a) 2kPa±0,2kPa;
b) 5kPa±0,5kPa;
c) lOkPa±1.OkPa;
d) 24 kPa ± 2,4 kPa.
NOTE 1 In case of the pressure loot of 10 mm diameter, the force is calculated from the pressure for each.
a) 0,157N±0,016N
b) 0,393 N ± 0,039 N
c) 0,785 N ± 0,079 N
d) l,88N±0,19N
NOTE 2 The actual pressure exerted by the presser foot can be calculated in one of the following ways:
a) by determining
1) the force exerted by the presser foot assembly, using a calibrated counterbalance, and
2) the surface area of the presser foot by direct measurement. or
b) by using a tension dial gauge.
4.3 Reference plate (anvil), having a plane upper surface of diameter not less than, preferably 50 mm greater than that of the presser foot (4.2).
4.4 Means for moving the pressure foot, in a direction normal to the upper surface of the reference plate so that its bearing surface is maintained parallel to the upper surface of the reference plate.ISO 2286-3 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…