ISO 6892-2-2011 pdf free download.Metallic materials – T ensile testing – Part 2: Method of test at elevated temperature.
This part of ISO 6892 specifies a method of tensile testing of metallic materials at temperatures higher than room temperature.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 6892-1:2009, Metallic materials — Tensile testing — Part 1: Method of test at room temperature
ISO 7500-1, Metallic materials — Verification of static uniaxial testing machines — Part 1:
Tension/compression testing machines — Verification and calibration of the force-measuring system
ISO 9513, Metallic materials — Calibration of extensometers used in uniaxial testing
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 6892-1:2009 apply with the following exceptions and supplements.
In general, all test piece geometries/dimensions are based on measurements taken at room temperature. The exception may be the extensometer gauge length (see 3.3 and 10.2.2).
3.1 original gauge length L。 gauge length measured at room temperature before heating of the test piece and before application of force
3.2 percentage elongation after fracture A permanent elongation at room temperature of the gauge length after fracture (Lu- Lo), expressed as a percentage of the original gauge length (Lo)
NOTE For further details, see IsO 6892-1:2009.
3.3 extensometer gauge length Le length within the parallel portion of the test piece used for the measurement of extension by means of an extensometer
3.4 extension increase in the extensometer gauge length (Lg) at a given moment during the test
4 Symbols and designations
Iso 6892-1:2009, Table 1 provides an extensive listing of symbols and their related designations.
The additional symbols used in this part of ISO 6892 are given in Table 1.
5 Principle
The test involves straining a test piece by tensile force for the determination of one or more of the mechanical properties defined in Clause 3.
The test is carried out at a temperature higher than 35 C, which means at temperatures higher than room temperature as specified in ISO 6892-1.
6 Test piece
For requirements concerning test pieces, see Iso 6892-1:2009, Clause 6.
NOTE Additional examples of test pieces are given in Annex A.
7 Determination of original cross-sectional area (S0)
For requirements concerning determination of the original cross-sectional area, see ISO 6892-1:2009, Clause 7.
NOTE This parameter is calculated from measurements taken at room temperature.
8 Marking the original gauge length (L0)
For requirements concerning marking the original gauge length, see ISO 6892-1:2009. Clause 8.
9 Apparatus
9.1 Force-measurIng system
The force-measuring system of the testing machine shall be calibrated in accordance with ISO 7500-1,
class 1, or better
9.2 Extensometer
For the determination of proof strength (plastic or total extension), the used extensometer shall be in accordance with ISO 9513, class 1 or better, in the relevant range. For other properties (with higher extension) an ISO 9513 dass 2 extensometer in the relevant range may be used.ISO 6892-2 pdf download.


Tags:
Related Downloads
  • ISO 8600-1-2013 pdf free download.Endoscopes  – Medical endoscopes and endotherapy devices – Part 1: General requirements. 6 Marking 6.1 Minimum marking Iach individual endoscope or endotherapy device shall have the lollowing minimum marking: a) model number and/or other mark sufficient to identify the endoscope or endotherapy device and its manufacturer; b) maximum insertion portion width, minimum instrument channel width, working length, field of view and/or direction of view where such identification is necessary for the intended use of the endoscope or endotherapy device. The Insertion portion width and instrument channel width units shall be in millimetres. The insertion portion width and instrument channel width can also be marked in French size as defined in 3.5, shown by either ‘Fr or an encircled number; c) wherever reasonable and practicable. the endoscope or endotherapy device and detachable component(s) shall be identified in terms of lot numbers or serial numbers, etc. 6.2 Marking legibility The marking shall remain legible over the lifetime of the device when the endoscope or endotherapy device is used, cleaned, disinlected, sterilized and stored in accordance with the instruction manual. 6.3 Marking exceptions When marking on the endoscope or endotherapy device or detachable component(s) is impossible to achieve due…

  • ISO 15688-2012 pdf free download.Road construction and maintenance equipment – Soil stabilizers 一 Terminology and commercial specifications. This International Standard establishes the terminology, definitions of operation and commercial specifications for soil stabilizers and their components intended for use in road construction and pavement works. It does not apply to soil stabilizers used in agricultural applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.. ISO 3911, Wheels and rims for pneumatic tyres — Vocabulary, designation and marking ISO 6746-1, Earth-moving machinery — Definitions of dimensions and codes — Part 1: Base machine ISO 6746-2, Earth-moving machinery — Definitions of dimensions and codes — Part 2: Equipment and attachments ISO 7134. Earth-moving machinery — Graders — Terminology and commercial specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 soil stabilizer self-propelled machine, either towed or transported, with the function of pulverizing, breaking-up, aerating, homogenizing, and loosening existing and imported soil or paving materials and mixing them…

  • ISO 18436-1-2012 pdf free.Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel一 Part 1: Requirements for assessment bodies and the assessment process. 5 Requirements for assessment body personnel 5.1 General provisions In order to ensure that the assessment process is carried out effectively and uniformly, the competence requirements for personnel involved in the entire process shall be defined by the assessment body and, in the case of a third party, be approved by the responsible TCC (in accordance with ISO/IEC 17024). The assessment body shall require its personnel (internal or external) to sign a contract, or other document, by which they commit themselves to comply with the rules defined by the assessment body, including those relating to confidentiality and those relating to independence from commercial and other interests, and from any prior or present link with the persons to be examined that would, in the opinion of the interested parties, compromise impartiality. Clearly documented instructions shall be available to the personnel, describing their duties and responsibilities. These instructions shall be maintained up to date. All personnel involved in any aspect of assessment activities shall possess appropriate educational qualifications, experience and technical expertise, which satisfy defined…